− | 1) For the public DS github-site codes, it only supports the classical generator dynamic model (the detailed models such as gensal, esst1a, and wsieg1 are only available from the internal svn site). | + | |
− | 2) For the classical dynamic generator dyr files, only 300-bus and 3000-bus systems are tested with gridpack and have a good match with powerworld results. When the bus size goes to 20000 bus, only detailed dynamic model dyr file works with Gridpack and has good match with powerworld, classical dynamic model does not work. | + | 1) For the public DS github-site codes, it only supports the classical generator dynamic model (the detailed models such as gensal, esst1a, and wsieg1 are only available from the internal svn site, please contact Dr. Shuangshuang Jin email: shuangshuang.jin@pnnl.gov for the source code of these detailed dynamic models). |
− | + | ||
+ | 2) For the classical dynamic generator dyr files, only 300-bus and 3000-bus systems are tested with gridpack and have a good match with powerworld results. When the bus size goes to 20000 bus, only detailed dynamic model dyr file works with Gridpack and has good match with powerworld, classical dynamic model does not work. | ||
+ | |||
+ | *[[Media:300bus.tar|300bus data]] | ||
+ | *[[Media:3000bus.tar|3000bus data]] | ||
+ | *[[Media:20000bus.tar|20000bus data]] | ||
+ | *[[Media:54815buscase.tar|54815 bus case data]] |
Latest revision as of 01:08, 3 March 2017
Developer's Note:
1) For the public DS github-site codes, it only supports the classical generator dynamic model (the detailed models such as gensal, esst1a, and wsieg1 are only available from the internal svn site, please contact Dr. Shuangshuang Jin email: shuangshuang.jin@pnnl.gov for the source code of these detailed dynamic models).
2) For the classical dynamic generator dyr files, only 300-bus and 3000-bus systems are tested with gridpack and have a good match with powerworld results. When the bus size goes to 20000 bus, only detailed dynamic model dyr file works with Gridpack and has good match with powerworld, classical dynamic model does not work.