Difference between revisions of "DynamicSimulations"

From GridPACK
Jump to: navigation, search
(Created page with "Developer's Note: 1) For the public DS github-site codes, it only supports the classical generator dynamic model (the detailed models such as gensal, esst1a, and wsieg1 are on...")
 
Line 1: Line 1:
 
Developer's Note:
 
Developer's Note:
 +
 
1) For the public DS github-site codes, it only supports the classical generator dynamic model (the detailed models such as gensal, esst1a, and wsieg1 are only available from the internal svn site).
 
1) For the public DS github-site codes, it only supports the classical generator dynamic model (the detailed models such as gensal, esst1a, and wsieg1 are only available from the internal svn site).
 +
 
2) For the classical dynamic generator dyr files, only 300-bus and 3000-bus systems are tested with gridpack and have a good match with powerworld results. When the bus size goes to 20000 bus, only detailed dynamic model dyr file works with Gridpack and has good match with powerworld, classical dynamic model does not work.
 
2) For the classical dynamic generator dyr files, only 300-bus and 3000-bus systems are tested with gridpack and have a good match with powerworld results. When the bus size goes to 20000 bus, only detailed dynamic model dyr file works with Gridpack and has good match with powerworld, classical dynamic model does not work.
 +
 
3) 179-bus system includes sensitive data and is not allowed for public access. The student from NCSU can first try the 300-bus and 3000-bus system, where I also include the xml files for his convenience for testing
 
3) 179-bus system includes sensitive data and is not allowed for public access. The student from NCSU can first try the 300-bus and 3000-bus system, where I also include the xml files for his convenience for testing

Revision as of 00:40, 3 March 2017

Developer's Note:

1) For the public DS github-site codes, it only supports the classical generator dynamic model (the detailed models such as gensal, esst1a, and wsieg1 are only available from the internal svn site).

2) For the classical dynamic generator dyr files, only 300-bus and 3000-bus systems are tested with gridpack and have a good match with powerworld results. When the bus size goes to 20000 bus, only detailed dynamic model dyr file works with Gridpack and has good match with powerworld, classical dynamic model does not work.

3) 179-bus system includes sensitive data and is not allowed for public access. The student from NCSU can first try the 300-bus and 3000-bus system, where I also include the xml files for his convenience for testing